200A Telecom Rectifier
Product Details:
Place of Origin: | China |
Brand Name: | ESTEL |
Certification: | ISO |
Model Number: | GPE48200E |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Set |
---|---|
Price: | Depending on order quantity |
Packaging Details: | carton + wooden case |
Delivery Time: | 15-20 days |
Payment Terms: | L/C, T/T |
Supply Ability: | 2000 sets per month |
Detail Information |
|||
Output Power: | 10700W | Output Voltage: | 48VDC |
---|---|---|---|
Input Voltage: | 220VAC | Input Over Voltage Protection Point: | 300Vac |
Input Under Voltage Protection Point: | 85Vac | Rectifier Module: | 50A*4 |
Monitoring Module: | With Ethernet Port | Power Factor: | 0.98 |
Highlight: | 200A Telecom Rectifier,10700W Telecom Rectifier,10700W rectifier used in telecommunication |
Product Description
Telecom Power System Rectifier Input 220VAC Output 48VDC 10700W 200A
With AC DC Power Distribution RS485
Model: GPE48200E
Introduction
The rectifier GPE48200E is applicable for outdoor telecom cabinet power supply. The rectifier system is flexible, efficient and reliable.
The highly efficient and innovative rectifier system contributes to a reduction in electrical energy consumption lessening your environmental impact. Using less energy means there is less heat to dissipate which in turn results in a reduced need for cooling providing another consequential saving.
Additionally the weight and volume of the rectifiers and distribution units was also reduced during development leading to further practical benefits and reduced resource use.
Features
- Adoption of active power factor compensation technology with factor >0.98
- Zero current/voltage switching tech with high efficiency ≥91%
- Reliable hot plug technology
- Wide operating range of AC input voltage: 90~290Vac
- DC output with consistent power
- Operating temperature range: -25°C~+55°C(for outdoor use)
- Lifecycle of battery prolonged by perfect battery management, including electrical charge/discharge management, battery temperature compensation, battery capacity test, reversal connection proof protection, low voltage protection etc.
- Input over/under voltage protection
- Output over voltage protection
- Output over current protection
- Output short circuit protection
- Auto current sharing, parallel output
- Embedded mounting
- Commissioning, expansion and replacement is a simple process
- Remote monitoring via RS485/232
System Configuration
The system consists of power distribution unit, rectifier module (from 1 set, up to 4 sets) and 1 monitoring module. The configuration is optional, as following table:
Configuration | Rectifier Module | Monitoring Module | Power Distribution |
Standard | GPR4850D-R01 | GPM48P-A (With Ethernet Port) |
AC power distribution: single-phase input, AC breaker @ general line (80A/2P) ; DC power distribution: Battery: MCB 125A×2; LVLD: no LVLD, but with LVLD alarm LVBD: 125A×5, 63A×2
|
Operating Principle
AC power is first input AC-INPUT MCB and then feed into the rectifier module after lightning proof and filtering. AC-INPUT acts as protection to over load and short circuit to AC power. The user’s battery is connected to the DC output side through MCB BAT and KM2, and the circuit breaker provides disconnection control, over-load and short-circuit protection to the battery.
Under normal conditions, every parameter of rectifier modules and power distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains faults, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When battery voltage is under -47V±0.5V, the monitoring module sends DC under voltage alarm signal and when battery voltage is under -46.0V±0.5V (adjustable), the KM1cuts off non-priority loads and retaining power to priority loads. If battery voltage drops to -43.0V±0.5V (adjustable), the KM2 will cut off output of priority loads and then the power system will stop working. If the external AC mains recovers, the system will normally work again. (All above monitoring data are system default values and can be reset by user).
Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding.
System Properties
Input | |||||
Item | Min. | Typical | Max. | Unit | Remark |
Input voltage range | 90 | 220 | 290 | Vac | |
Input frequency | 45 | 50 | 65 | Hz | |
Max. Input current | 67 | A | |||
Power factor | 0.98 | Rated load | |||
Input over voltage protection point | 300 | Vac | Automatically recoverable | ||
Input over voltage recovery point | 290 | Vac | Return difference ≥5V | ||
Input under voltage protection point | 85 | Vac | Automatically recoverable | ||
Input under voltage recovery point | 90 | Vac | Return difference ≥5V | ||
Input over current protection | MCB in AC Input supply protection |
Output | |||||
Item | Min. | Typical | Max. | Unit | Remark |
Output voltage | 42 | 53.5 | 58 | Vdc | Adjustable by monitor, tested in no load |
Output power | 10700 | W | 10700W output when input voltage is 176~290VAC (rated power includes battery charging power plus load power) | ||
5350 | W | 90~175VAC input | |||
Output over voltage protection point | 58.5 | 60.5 | Vdc | Lock up | |
Output current limiting protection point | Output current limiting protection | ||||
Output short circuit protection | Long-term short circuit protection, automatically recoverable | ||||
Over temperature protection | Automatically recoverable in ambient temperature lower than 65°C | ||||
Battery power-down protection | Battery power-down protection | ||||
Battery polarities reversal connection protection | No damage on battery and power system | ||||
Voltage regulation accuracy | ±1 | % |
Mechanical Property
Mechanical specifications | |
Dimensions (Overall) | as the following diagram |
Weight(kg)(Overall) |
≤23.5kg (Inclusive of module) ≤13.5kg (Frame + Distribution, exclusive of module) |