Double Doors 19 Inch Outdoor Telecom Enclosure One Compartment
Product Details:
Place of Origin: | China |
Brand Name: | ESTEL |
Certification: | ISO9001, CE, RoHs |
Model Number: | ET7575150-209-9 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Set |
---|---|
Price: | Negotiation |
Packaging Details: | Wooden Case |
Delivery Time: | 3-4 weeks |
Payment Terms: | L/C, Western Union, T/T |
Supply Ability: | 5000 pcs/month |
Detail Information |
|||
External Dimension: | W×D×H 750×750×1750mm | 19” Rail: | Include |
---|---|---|---|
Galvanized Steel: | Include | Powder Coat: | Include |
Layout: | One Compartment | Door: | Double Doors |
Highlight: | 19 inch Outdoor Telecom Enclosure,Double Doors Outdoor Telecom Enclosure,19 Inch outdoor weatherproof box |
Product Description
Double Doors 19 Inch Outdoor Telecom Enclosure One Compartment
1. Outdoor Telecom Cabinet
Outdoor cabinet offers standard 19” racking rails, is a new design for telecom projects and surveillance projects., an Outdoor cabinet is vital in any industrial set up or any other related application for that matter.What happens is that you always need a high standard of efficiency whenever you’re undertaking a particular operation.Ordinarily, you need a Outdoor battery Enclosure to guarantee safety both for the users and the battery.Having this equipment is a sure way of becoming safe especially from the aspect of accidents.
2. Selling points and Features
- External Dimension W×D×H 750×750×1750mm
- 19” rail
- The highest protection against corrosion
- Galvanized steel Polyester Powder coat
- IP55 dust and water protection
- Vandal-proof
- Compact design
- Ready for crane transport
- Cable entry from underearth
3. Technical Parameters
Item | Type | Technical Parameter |
Structure | Dimension | External Dimension W×D×H 750×750×1750mm |
Layout | One compartment | |
Equipment Installation Method | 19” standard rack | |
Door | Double Doors; with special lock for outdoor cabinet (support padlock) | |
Material | Galvanized steel; double walls, thickness of outer plate: 1.2mm, thickness of inner plate: 0.8mm, with heat insulation between two walls. | |
Structure | Assembled | |
Ingress Protection | IP55 | |
Temperature Control | Cooling | 1200W Air Conditioner and 2 fans |
Lighting | LED lamp | 48V LED lamp |
Temperature | Temperature | Working Temperature: -40°C ~ +55°C |
Storage Temperature: -50°C ~ + 70°C | ||
Transport Temperature: -50°C ~ +70°C |
4. Accessories List
No. | Item | Quantity | Unit | Specs |
1 | Outdoor Telecom Cabinet | 1 | Set |
(1) External Dimension W×D×H 750×750×1750mm (2) Double Door ; with special lock for outdoor cabinet (support padlock) (3) Material: galvanized steel; double walls, thickness of outer plate: 1.2mm, thickness of inner plate: 0.8mm, with heat insulation between two walls. |
2 | Air Conditioner | 1 | Set | 1200W Air Conditioner, AC220V power supply |
3 | 110V To 220V Transformer | 1 | Set | Used for air conditioner input |
4 | Fans | 2 | PC | DC48V |
5 | Power Distribution Unit | 1 | Set |
Grade B Lightning Proof 2 x 63A/1P 2x32A/1P 2x16A/1P 2x10A/1P 2x5A/1P Height: 3U |
6 | Embedded Telecom Power System (UPS) | 1 | Set |
DC48V, 90A, 4800W; Model: GPE4890J |
7 | Package | 1 | Set | Wooden Case |
8 | Sensor | Sensors (including 1 smoke sensor, 2 door alarm, 2 LED lamp, 1 water sensor, and 1 temperature and humidity sensor.) |
5. Sensor
1 smoke sensor
2 door alarm
2 LED lamp
1 water sensor
1 temperature and humidity sensor.
6. Cabinet Structure
(1) External Dimension W×D×H 750×750×1750mm
(2) One compartment;
(3) totally two doors; with special lock for outdoor cabinet (support padlock)
(4) Material: galvanized steel; double walls, thickness of outer plate: 1.2mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.
7. Cabinet Mounting Type
· Wall mounting type
· Pole mounting type
· Floor standing by base
8. Cabinet Picture:
9. Embedded Telecom Power System (UPS)
DC48V, 90A, 4800W; Model:
GPE4890J
10. Grounding Protection
The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
Protective earthing of other equipments inside the cabinet should be connected to the grounding bar
FAQ
Q1: Are you a manufacturer?
A: Yes, we are a experienced manufacturer with our own design and production lines.
Q2. Do you have any MOQ limit for outdoor cabinet ?
A: Low MOQ, 1pc for sample checking is available.
Q3: Can I get sample order?
A: Yes, we would like to get your sample order for testing our quality, the sample cost is paid by the customer.
Q4: Are you able to customize items with design or logo?
A: Yes, OEM & ODM is available.
Q5: How do you ship the goods and how long it will take?
A: We normally make shipment by sea or air which usually takes about 10- 50 days depend on the destination.
Q6: How long is the product warranty ?
A: We guarantee all our products 12 months warranty.