0.5W 12VDC Water Sensor Preventing Water Leakage
Product Details:
| Place of Origin: | China |
| Brand Name: | ESTEL |
| Certification: | ISO |
| Model Number: | EA5316001 |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1PC |
|---|---|
| Price: | Depending on quantity |
| Packaging Details: | carton |
| Delivery Time: | 15 days |
| Payment Terms: | L/C, T/T |
| Supply Ability: | 10000pcs per month |
|
Detail Information |
|||
| Power Supply: | 12VDC | Output Mode: | Relay (Load Current:30mA) ,Relay Output NC\NO Optional |
|---|---|---|---|
| Static Power Consumption: | <0.3W | Maximum Alarm Power Consumption: | 0.5W |
| Load Capacity: | VH Is 5V Or 12V(± 0.5V) | Installation: | Installed At Bottom Of Outdoor Telecom Cabinet |
| Operating Humidity: | 20%RH ~ 100%RH | Solid-state Relays: | ≤500mA |
| Highlight: | 12VDC Water Sensor,0.5W Water Sensor,0.5W Water Detector |
||
Product Description
12VDC Water Detector Water Sensor For Detecting Water Leakage Or Flood
In Outdoor Telecom Enclosure
Model: EA5316001
Application
Water leak control in outdoor telecom cabinet with electronic devices or telecom equipments is an elementary part in outdoor telecom cabinet protection.
Undetected leaks may cause substantial damage:
• Damage to equipment
• Health risk to personnel
• Increased fire risk
• Environment pollution
• Lost of product
Technical Parameters
- Power supply: 12VDC
- Operating temperature: -10°C~50°C
- Output mode: Relay (Load current:30mA) ,Relay output NCNO optional
- Static power consumption: <0.3W
- Maximum alarm power consumption: 0.5W
- Operating humidity:20%RH ~ 100%RH
- False positive rate:<100ppm
- High and low level outputs:VL is 0V (+0.5V)
- Load capacity: VH is 5V or 12V(± 0.5V)
- Solid-state relays:≤500mA (High current can reach 1A and need to be custom-made)
- High and low levels ≥ 3k.(Remark: The supply voltage should be higher than 16V at a high level output of 12V)
Wiring Instructions
| Color | Instruction |
| Red | Working Voltage +12VDC, positive pole |
| Black | Working Voltage -12VDC , negative pole |
| Yellow | Normally closed contact output, No polarity difference |
| Blue | Normally open contact output, No polarity difference |
| Brown | Signal public end, No polarity difference |
Product Pictures
![]()