Air Cooling Waterproof Cabinet with 2U Compact Base Station DC Power System
Product Details:
| Place of Origin: | Shenzhen, China (Mainland) |
| Brand Name: | ESTEL |
| Certification: | ISO9001, CE, 3C, FCC |
Payment & Shipping Terms:
| Delivery Time: | 25-30 working days |
|---|
|
Detail Information |
|||
| Product Type: | Telecom DC Power Cabinet | Dimension: | H1000 × W750 × D750mm |
|---|---|---|---|
| Rack: | 16U Of 19-inch Rack | Rectifier System: | 5.22kW(N+1) |
| AC Input: | 220VAC Single Phase | Rectifier Module: | 1.74kW |
| DC Output: | -43V To -58VDC (rated -53.5VDC) | Controller: | MC2600 |
| Highlight: | waterproof air cooling cabinet,2U compact base station power system,DC power telecom rectifier |
||
Product Description
Air Cooling Waterproof Cabinet with 2U Compact Base Station DC Power System
Overview of Base Station DC Power Cabinet
Basement telecom stations present a different set of conditions from outdoor cabinets. Ambient temperature is generally stable, but airflow is restricted, equipment is stacked densely, and maintenance access is often constrained by the room layout rather than the cabinet itself. This 5.22kW DC power cabinet is configured for that environment.
The enclosure is IP55-rated, measures H1000 × W750 × D750mm with a 150mm plinth, and provides 16U of 19-inch rack space. The 2U rectifier system and the equipment it powers share the cabinet, with a 500W air conditioner and 20mm thermal insulation cotton maintaining internal temperature.
Power System of Base Station DC Power Cabinet
The rectifier system is a 2U, 48V DC distribution unit with a total output capacity of 5.22kW, built from three 1.74kW rectifier modules in N+1 redundancy. Conversion efficiency exceeds 93% across most of the load range, which keeps heat generation inside the cabinet lower and reduces the load on the air conditioner.
The system operates from a single-phase 220VAC input and delivers a regulated DC output adjustable from –43V to –58V, typically set at –53.5V. The output serves both active and passive telecom equipment within the cabinet.
Controller of Base Station DC Power Cabinet
| Interface | Quantity / Type |
| Analog Inputs (AI) | 3 total — 2 battery temperature, 1 ambient temperature |
| Digital Inputs (DI) | 7 for external status monitoring |
| Digital Outputs (DO) | 6 for alarm and control signaling |
| Display | LCD for real-time monitoring and configuration |
| Communication | RS485 and SNMP |
The AI configuration is worth noting: two battery temperature sensors plus one ambient temperature sensor. Battery temperature is monitored independently, which allows the charge profile to account for the battery's actual thermal condition rather than assuming it matches the room. The RS485 and SNMP interfaces connect to existing network management or building management systems.
Cooling of Base Station DC Power Cabinet
A 500W air conditioner, rated 200–240VAC at 50/60Hz, handles thermal management, supported by 20mm thermal insulation cotton in the cabinet walls. In a basement environment, the air conditioner is working against equipment heat rather than external heat gain, and the insulation limits transfer through the enclosure surfaces.
Cabinet of Base Station DC Power Cabinet
| Parameter | Specification |
| IP Grade | IP55 |
| External Dimensions | H1000 × W750 × D750mm (customizable), 150mm plinth |
| Internal Space | 16U, 19-inch bracket |
| Material | 1.2mm galvanized sheet, single layer |
| Insulation | 20mm thermal insulation cotton |
| Coating | Polyester powder coating |
| Color | RAL7035 |
| Lock | Anti-theft three-point locking system |
| Hinge | Inner hinge |
| Installation | Floor mounted |
| Cable Entry | Bottom in/out |
| Maintenance | One front door, front maintenance |
| LED Lamp | 220VAC, 50Hz |
![]()
![]()
![]()